Fire Safety Guide · Lebanon
Fire Extinguisher Prices in Lebanon (2025) + Where to Buy in Your City
Aligned with EN 2 / EN 3, BS 5306 and NFPA 10 where applicable.
Types, sizes & safe selection (with standards notes)
Pricing: Due to currency changes, we provide live quotes via WhatsApp. Use the city links below.
| Type | Common sizes | Typical use / class | Standards notes |
|---|---|---|---|
| ABC Dry Powder | 1kg · 2kg · 4kg · 6kg · 9kg | Versatile across A/B/C hazards | Effective but can impair visibility & leave residue. Selection for indoor/public areas should follow BS 5306-8:2023 guidance (risk-based). |
| CO₂ | 2kg · 5kg | Electrical equipment; some Class B | No post-cooling → re-ignition risk. Use in ventilated spaces. Avoid frostbite on the horn. |
| Foam (AFFF) | 6L · 9L | Class B (and some A) | Not for energized electrical equipment. |
| Water / Water-mist | 6L · 9L | Class A | Only on live electrical if clearly EN 3 dielectric-rated (check the label). |
| Wet Chemical | 6L | Commercial kitchens (Class F / K) | Saponifies hot oils/fats and cools surfaces (for deep-fat fryers & hoods per kitchen standards). |
| Class D agents | Specialized | Combustible metals (D) | Use only the agent listed for the specific metal per SDS/manufacturer. |
- EU classes (EN 2): A/B/C/D/F. NFPA (US): A/B/C/D/K. “Electrical” is a hazard condition in EU practice; use agents suitable/marked for live electrical.
- EN 3 dielectric test marking indicates suitability for use on live electrical equipment.
- Powder indoors: apply BS 5306-8:2023 selection cautions for public interiors (visibility/air quality).
Inspection & maintenance (NFPA 10 vs BS 5306-3)
NFPA 10 (US practice)
- Monthly owner inspection; Annual maintenance by qualified person.
- 6-year internal examination for many stored-pressure dry chemical units.
- Hydrostatic testing cycles typically: water/foam/CO₂/wet chemical every 5 years; dry chemical every 12 years (verify nameplate).
BS 5306-3 (UK/EU practice)
- Monthly visual checks by the Responsible Person; Annual service by a competent technician.
- Extended service/discharge intervals typically: water/foam/powder every 5 years; CO₂ typically 10 years (UK practice differs from NFPA).
Always follow your AHJ (Authority Having Jurisdiction) and the manufacturer’s instructions for your project in Lebanon.
Where to buy by city (Lebanon)
We supply, deliver, install, and maintain across Lebanon. Quick WhatsApp links below.
Beirut
Mixed-use/high-rise and underground parking create combined Class A/B and energized-equipment risks. Provide Class A coverage by floor area and travel distance (A ≤ 75 ft / 22.9 m) and ensure suitable agents where electrical equipment is present (e.g., CO₂ or EN 3 dielectric-rated units). Site on egress routes and near switchgear/UPS rooms; maintain monthly owner checks and annual servicing (NFPA 10 / BS 5306-3).
NFPA 10 / BS 5306-3 &-8 · EN 2 / EN 3
Tripoli
Port/industrial workshops and traditional markets may involve Class B liquids (fuels/solvents) and live electrical panels. Base selection on a documented risk assessment; maintain Class B travel distances (≈ 30–50 ft depending on rating) and place agents suitable for energized equipment where required. Include spill-control and safety signage where flammables are stored or handled.
NFPA 10 / BS 5306-8 · EN 2 / EN 3
Saida
Commercial kitchens require Class F/K wet-chemical extinguishers sized to the appliances and coordinated with the hood/suppression design per AHJ requirements. Provide Class A coverage for dining/retail areas, and assess gas storage/valves and shut-off access. Do not substitute ABC powder for deep-fat fryer fires.
NFPA 10 / NFPA 96 · BS 5306-8
Zahlé / Bekaa
Distribution/warehousing and agro-industry protection depends on commodity class and aisle layout. Confirm Class A rating by floor area; treat flammable-liquid handling and battery-charging bays as B/E hazards with appropriate agents and spacing. Add spill kits, clear aisle signage, and unobstructed mounting heights per siting rules.
NFPA 10 / BS 5306-8
Jounieh / Keserwan
For offices/clinics/hospitality, plan Class A coverage by floor area and travel distance, and add agents suitable for energized equipment at IT racks and panels (CO₂ or EN 3 dielectric-rated water-mist). Keep egress routes and door swings clear, use compliant signage, and schedule monthly visual checks plus annual servicing.
NFPA 10 / BS 5306-3 &-8 · EN 3
Byblos / Jbeil
Heritage/tourism interiors often need non-intrusive mounting and coordinated wayfinding. Select media and fixings that preserve finishes and visibility. Apply BS 5306-8:2023 guidance when evaluating powder in busy interiors (visibility/air quality), and document positioning along escape routes at the correct mounting heights.
BS 5306-8 · EN 2 / EN 3
Tyre / Sour
Coastal environments introduce salt-air corrosion. Use corrosion-resistant brackets/cabinets, inspect for corrosion more frequently, and verify hydrostatic/servicing intervals remain in date. Protect outdoor units from sun and tampering, and ensure access/marking comply with siting requirements.
NFPA 10 / BS 5306-3
Nabatieh / South
Determine coverage using floor-area and travel-distance methods, position along escape routes without obstruction, and match agents to room-specific risks (science labs, kitchens, electrical rooms). Implement monthly owner checks, annual servicing, and periodic staff drills per the applicable standard.
NFPA 10 / BS 5306-3 &-8
Baalbek / Hermel
Use a task-based hazard assessment (flammable liquids/gases, combustible metals, energized equipment). Provide agents matched to each hazard and verify travel distances/ratings meet NFPA 10 / BS 5306-8. Implement hot-work permitting, staff training, and periodic drills; keep records for inspections.
NFPA 10 / BS 5306-8
FAQ
Which standard should I follow in Lebanon?
Follow your project’s AHJ (consultant/inspector). We supply per EN/BS or NFPA specifications as required.
Can I use water on electrical?
Only if the specific extinguisher is explicitly EN 3 dielectric-rated for live electrical equipment, or the circuit is de-energized.
Who checks extinguishers and how often?
Monthly visual checks by the owner/responsible person; annual servicing by a competent/qualified technician (NFPA 10 / BS 5306-3).
Emergency number in Lebanon?
Civil Defense: 125. Always raise the alarm and call first.
Need today’s price or a quick site check?
We deliver across Lebanon and handle installation and annual maintenance.
Chat on WhatsAppدليل السلامة من الحرائق · لبنان
أسعار طفايات الحريق في لبنان (2025) وأين أشتري حسب المدينة
بما يتوافق مع EN 2 / EN 3 و BS 5306 و NFPA 10 حيثما يلزم.
الأنواع والأحجام والاختيار الآمن (مع ملاحظات المعيار)
الأسعار: بسبب تغيّر العملة، نوفّر عرض سعر فوري عبر واتساب. استخدم روابط مدينتك أدناه.
| النوع | الأحجام الشائعة | الاستخدام / الفئة | ملاحظات المعيار |
|---|---|---|---|
| بودرة ABC | 1كغ · 2كغ · 4كغ · 6كغ · 9كغ | تغطية واسعة لمخاطر A/B/C | فعّالة لكنها قد تؤثر على الرؤية وتترك بقايا؛ اختيارها للأماكن الداخلية/العامة يجب أن يتبع BS 5306-8:2023 (حسب تقييم المخاطر). |
| ثاني أكسيد الكربون (CO₂) | 2كغ · 5كغ | المعدات الكهربائية وبعض فئة B | لا تبريد بعدي → احتمال عودة الاشتعال؛ تُستخدم في أماكن جيدة التهوية وتُجنب ملامسة البوق للجلد. |
| رغوي (Foam) | 6لتر · 9لتر | فئة B (وبعض A) | غير مناسب للمعدات الكهربائية الموصّلة. |
| ماء / رذاذ ماء | 6لتر · 9لتر | فئة A | على الكهرباء الحية فقط إذا كانت الطفاية تحمل تصنيف عزل EN 3 (تحقّق من الملصق). |
| كيميائي رطب | 6لتر | مطابخ المطاعم (فئة F / K) | يُكوّن طبقة صابونية تبريدية على زيوت/دهون القلي الحارة. |
| عوامل فئة D | متخصص | معادن قابلة للاحتراق | يُستخدم فقط العامل المحدد للنوع المعدني حسب تعليمات الشركة/ورقة بيانات السلامة. |
- فئات الاتحاد الأوروبي (EN 2): A/B/C/D/F. وNFPA (الولايات المتحدة): A/B/C/D/K. الكهرباء ليست فئة منفصلة في أوروبا؛ بل حالة خطِرة وتُستخدم وسائط مناسبة/معلّمة للاستخدام على الكهرباء.
- اختبار العزل EN 3 يدل على صلاحية الاستخدام على الكهرباء الحية.
- البودرة في الأماكن الداخلية: اتبع إرشادات BS 5306-8:2023 في الأماكن العامة (الرؤية/جودة الهواء).
الفحص والصيانة (NFPA 10 مقابل BS 5306-3)
NFPA 10 (الممارسة الأمريكية)
- شهريًا فحص بصري من المالك؛ سنوياً صيانة من مختص.
- فحص داخلي كل 6 سنوات لكثير من طفايات البودرة المضغوطة.
- اختبار الضغط عادةً: ماء/رغوة/CO₂/كيميائي رطب كل 5 سنوات؛ وبودرة كل 12 سنة (تحقّق من لوحة البيانات).
BS 5306-3 (الممارسة البريطانية/الأوروبية)
- شهريًا فحص بصري من المسؤول؛ سنوياً صيانة من فني مختص.
- خدمة موسعة/تفريغ عادةً: ماء/رغوة/بودرة كل 5 سنوات؛ وCO₂ عادةً كل 10 سنوات.
اتبع متطلبات الجهة المخوّلة (AHJ) وتعليمات الشركة المصنّعة لمشروعك في لبنان.
الشراء حسب المدينة (لبنان)
نوفّر التوريد والتركيب والصيانة مع التوصيل إلى جميع المناطق. روابط واتساب السريعة أدناه.
بيروت
الاستخدامات المختلطة/الأبراج ومواقف السيارات السفلية تولّد مخاطر مشتركة من الفئتين A/B ومعدات كهربائية موصّلة. احسب تغطية الفئة A حسب المساحة ومسافة الوصول (≤ 22.9م)، واستخدم وسائط مناسبة حيث توجد كهرباء (مثل CO₂ أو طفايات حاصلة على تصنيف العزل EN 3). ثبّت الوحدات على مسارات الإخلاء وبالقرب من غرف اللوحات/UPS، مع فحص شهري وصيانة سنوية (NFPA 10 / BS 5306-3).
NFPA 10 / BS 5306-3 و-8 · EN 2 / EN 3
طرابلس
الورش المينائية والأسواق التقليدية قد تشمل سوائل قابلة للاشتعال (فئة B) وألواح كهربائية. يعتمد الاختيار على تقييم مخاطر موثّق؛ حافظ على مسافات الوصول لفئة B (≈ 9–15م حسب التصنيف) وضع وسائط مناسبة للكهرباء حيث يلزم. أضِف أطقم معالجة الانسكابات ولافتات السلامة حيث يتم تخزين المواد القابلة للاشتعال أو تداولها.
NFPA 10 / BS 5306-8 · EN 2 / EN 3
صيدا
المطابخ التجارية تحتاج طفايات كيميائي رطب (فئة F/K) بحجم مناسب للأجهزة وبالتنسيق مع نظام الشفاط/الإطفاء حسب متطلبات الجهة المخوّلة. وفّر تغطية فئة A لصالات الطعام/البيع، وقيّم تخزين الغاز وصمامات الإقفال والوصول إليها. لا تُستبدل بودرة ABC في حرائق الزيوت العميقة.
NFPA 10 / NFPA 96 · BS 5306-8
زحلة / البقاع
حماية التوزيع/المستودعات والقطاع الزراعي تعتمد على تصنيف البضائع وتخطيط الممرات. ثبّت تصنيف الفئة A حسب المساحة؛ واعتبر مناطق تداول السوائل القابلة للاشتعال ومحطات شحن البطاريات مخاطر B/كهربائية بوسائط ومسافات مناسبة. أضف أطقم الانسكابات ولافتات واضحة وارتفاعات تثبيت غير معيقة.
NFPA 10 / BS 5306-8
جونية / كسروان
للمكاتب/العيادات/الفنادق: خطّط لتغطية فئة A حسب المساحة ومسافة الوصول، وأضف وسائط مناسبة للكهرباء في رفوف الـ IT والألواح (CO₂ أو رذاذ ماء مع تصنيف EN 3). حافظ على خلو مسارات الإخلاء واللافتات المعيارية، ونفّذ فحصًا شهريًا وصيانة سنوية.
NFPA 10 / BS 5306-3 و-8 · EN 3
جبيل / بيبلوس
البيئات التراثية/السياحية تحتاج تثبيتًا غير مُشوِّه وتنسيقًا مع لافتات الإخلاء. اختر وسائط وتثبيتات تحافظ على التشطيبات والرؤية. اتبع BS 5306-8:2023 عند تقييم البودرة في الأماكن المزدحمة (الرؤية/جودة الهواء)، ووثّق التموضع على مسارات الهروب وارتفاعات التثبيت الصحيحة.
BS 5306-8 · EN 2 / EN 3
صور
البيئات الساحلية تُسرّع التآكل. استخدم حوامل/خزائن مقاومة للتآكل، وكثّف التفتيش على الصدأ، وتحقق من صلاحية اختبارات الضغط/الصيانة. احمِ الوحدات الخارجية من الشمس والعبث وتأكد من أنّ الوصول/اللافتات متوافقة.
NFPA 10 / BS 5306-3
النبطية / الجنوب
حدّد التغطية باستخدام طريقتي مساحة الأرضية ومسافة الوصول، وثبّت على مسارات الإخلاء دون إعاقات، وطابق الوسائط مع مخاطر الغرف (مختبرات علمية، مطابخ، غرف كهرباء). نفّذ فحصًا شهريًا وصيانة سنوية وتمارين دورية للموظفين.
NFPA 10 / BS 5306-3 و-8
بعلبك / الهرمل
اعتمد تقييمًا مهنيًا قائمًا على المهام (سوائل/غازات قابلة للاشتعال، معادن، معدات كهربائية). وفّر وسائط مطابقة لكل خطر وتحقق من مسافات الوصول/التصنيفات وفق NFPA 10 / BS 5306-8. نفّذ تصاريح العمل الساخن وتدريبًا وتمارين دورية، واحفظ السجلات للتفتيش.
NFPA 10 / BS 5306-8
الأسئلة الشائعة
أي معيار أتبع في لبنان؟
اتبع متطلبات الجهة المخوّلة (AHJ). نوفّر حسب مواصفات EN/BS أو NFPA حسب المشروع.
هل أستخدم الماء على الكهرباء؟
فقط إذا كانت الطفاية تحمل تصنيف العزل EN 3 للاستخدام على كهرباء حية، أو بعد فصل التغذية.
من يفحص الطفايات وكم مرة؟
فحص شهري بصري من المسؤول/المالك؛ وصيانة سنوية من فني مختص (NFPA 10 / BS 5306-3).
رقم الطوارئ في لبنان؟
الدفاع المدني: 125. أطلق الإنذار واتصل أولًا.